medical product
Products

High Performance Butterfly Electrode Pads - 3M Pre-Wire Disposable Neutral Electrode – Quanding

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

To be the stage of realizing dreams of our employees! To build a happier, more united and more professional team! To reach a mutual benefit of our customers, suppliers, the society and ourselves for Stimulator Machine Price , Tens Machine Pads , Ecg Snap Connector , We have been searching ahead to even better cooperation with overseas buyers dependant on mutual benefits. Be sure to really feel totally free to speak to us for additional element!
High Performance Butterfly Electrode Pads - 3M Pre-Wire Disposable Neutral Electrode – Quanding Detail:

Product Specification 

For Adult For Child Infant
QD202B-A QD202B-P QD202B-1
Bipolar /Split Monopolar/single Bipolar/Monopolar
102*202mm 90*148mm 53.5*124mm
Packaging 1pc/foil bag

350pcs/carton

 
Carton Size 45*45*28CM

GW: 15.4kg

 
Certification ISO13485,CE  

Storage

 

The product must be stored in its original package at the environmental conditions (temperature and relative humidity) specified on the pouch’s label. Putting external heavy weights on the package could damage the product.

Product  Instructions.

1. Select a well convex area (muscle) next to the area to be operated but at least 20 cm far from it, possibly on the forearm, on the thigh or on a whip. Eventually move the plate in order that the longer side is perpendicular to the area of the operation (see the picture). Avoid that the plate is superimposed.

2.NB Current should flow in parallel to the body surface and never pass through the thorax. The patient must be placed on a dry and perfectly isolated surface. The patient must be kept isolated from conductive parts and the operating bed must be earthed. Use dry gauzes to avoid that different areas of the body come into contact with each other.

3. Do not place the plate on wounds and scars, near bone projections, very adipose tissues, close to metallic prosthesis or to ECG electrodes

or on areas, where liquids can flow.

4.Do not place the plate on areas, where it can be subjected to pressure or under patient’s weight.

5.Shave the selected area, clean carefully and skim in order to remove eventual remaining of cream or cosmetics. Dry the selected area.

6.NB Do not use inflammables during the patient’s preparation. Do not use alcoholic substances or benzoine tincture.

7.Eventual shave remaining or hair can cause burns.

Application

  1.  After controlling the packing for damages, check the plates and gel. Do not use the product  in the case of damages or visible defects. Instead, return it to FIAB.
  2. Only open package immediately before use.
  3. Take off the protection film and place the plate on the prepared area; place it starting from a     side and continue with same pressing until the opposite side.
  4. Make sure that the entire surface of the plate is in contact with the patient’s skin.
  5. Avoid excessive contact between fingers and adhesive. Do not touch the gel . NB There must not be air bubbles or parts of the adhesive support not perfectly close to the patient.
  6. Connect the plate to the high-frequency generator using the connectorcable .   For neutral plate without connection cable: lift the connector lever and plug in the tongue.Make sure to plug in the tongue until the end, then close the lever. Then connect the generator to the pencil and the eventual foot control.

Warning

        1.  This is a disposable product – do not re-use.

        2.  The product is supplied not sterile – do not sterilize.

        3. Do not re-position or cut the plate, do not add gel.

        4. Do not use the product in case:

        5. The packaging is not complete

        6.There are evident damages on the plate or on the connection cable, Gel is not homogeneous or is dry.

        7.Do not submit a patient with implanted pacemaker to electrosurgical current without first consulting a cardiologist.

        8. The devices are to be used by trained healthcare professionals in electrosurgical procedures.

        9. Do not use paediatric plates for high-power procedures (such as trans-urethral resection – TUR).


Product detail pictures:

High Performance Butterfly Electrode Pads - 3M Pre-Wire Disposable Neutral Electrode  – Quanding detail pictures

High Performance Butterfly Electrode Pads - 3M Pre-Wire Disposable Neutral Electrode  – Quanding detail pictures

High Performance Butterfly Electrode Pads - 3M Pre-Wire Disposable Neutral Electrode  – Quanding detail pictures

High Performance Butterfly Electrode Pads - 3M Pre-Wire Disposable Neutral Electrode  – Quanding detail pictures

High Performance Butterfly Electrode Pads - 3M Pre-Wire Disposable Neutral Electrode  – Quanding detail pictures


Related Product Guide:

We goal to understand excellent disfigurement from the manufacturing and supply the top support to domestic and abroad clients wholeheartedly for High Performance Butterfly Electrode Pads - 3M Pre-Wire Disposable Neutral Electrode – Quanding , The product will supply to all over the world, such as: Puerto Rico, El Salvador, South Africa, Thus far, our item associated with printer dtg a4 may be shown in most foreign nations as well as urban centers, which are sought after simply by targeted traffic. We all highly imagine that now we have the full capacity to present you with contented merchandise. Desire to collect requests of your stuff and produce the long-term co-operation partnership. We very seriously promise:Csame top quality, better price; exact same selling price, higher quality.
  • This enterprise in the industry is strong and competitive, advancing with the times and develop sustainable, we are very pleased to have a opportunity to cooperate!
    5 StarsBy Nicola from Honduras - 2017.01.28 18:53
    The company can think what our think, the urgency of urgency to act in the interests of our position, can be said this is a responsible company, we had a happy cooperation!
    5 StarsBy Laura from Germany - 2017.08.15 12:36