Disposable Diathermy Electrosurgical Pencil,Surgical Cautery Pencil
Electrosurgical Pencil

Disposable Diathermy Electrosurgical Pencil,Surgical Cautery Pencil

    product detail

    Product Specification Model QD1001 Disposable yes Pencil color Blue Control type Hand control ,button swith Electrode type 70mm stainless steel tip Cable length 3m PVC-medical cable Maximaloutput current 1A Frequency confine 0-1MHZ Package 1pc/paper bag 200pcs/carton,69*30*38Cm GW:17KG  NW:16.5KG  Type Of Sterilization  Ethylene Oxide Sterilization(EO) Certification ISO13485,CE Product Advantage Designed with the surgeon in mind • Slim and lightweight, tapered ergonomic design, streamlined design, • Slip-proof handling and water resistant Rocker or Push-Button Switch • Switch and buttons designed for smooth activation • Equip with a range of monopolar cutting and coagulation electrodes to satisfy all users requirements. • With hexagonal shape to protect against inadvertent twisting, the electrodes can be locked safely into place and are easily exchanged and replaced. • The Disposable ESU Pencil - This cutting-edge tool is designed to provide precise and efficient tissue cutting and coagulation during surgical procedures. With a force cut & coag button switch and a standard 3-pin banana plug connector, this pencil offers the perfect balance of sensitivity and control. • The Disposable ESU Pencil is equipped with a 3M PVC cable, ensuring reliable and consistent performance throughout the procedure. Its appropriate switch sensitivity allows for seamless transitions between cutting and coagulation, making it an essential tool for surgeons and medical professionals. > One of the key features of our Disposable ESU Pencil is its fully disposable and sterile design. This eliminates the need for reprocessing and sterilization, saving valuable time and resources in the operating room. Additionally, the 100% sterile construction ensures the highest level of patient safety and reduces the risk of cross-contamination. >  The pencil’s ability to make precise cuts through tissue while simultaneously cauterizing to minimize bleeding makes it an indispensable tool for a wide range of surgical procedures. Whether it’s a delicate incision or a controlled coagulation, the Disposable ESU Pencil delivers consistent and reliable performance. > Furthermore, the pencil features a 10-foot cord, providing ample flexibility and reach for the surgical team. The 3-prong connector ensures a secure and stable connection, allowing for uninterrupted power delivery throughout the procedure.

    Product Specification

    Model Number TE-A23
    Sizes 50*50mm
    Backing Non-woven/PU/PET/Foam
    Connector size 2.0mm/2.5mm
    Gel Chinese gel/Japanese gel/American gel
    Color White, Black, Blue,Brown, Pink,Option
    Packing 4pcs/film/foil bag
    Report ROHS/Biocompatibility report
    Certificate CE/ISO/FDA

    description2

    Product Advantage

    • COMFORTABLE TENS REPLACEMENT PADS: This tens pads have white non-woven backing with black carbon conductor and premium gel adhesive, flexibly conforms to various body parts, effectively pain relief for arms, ankles, backs, legs, feet, elbow, hip, thigh, wrist, calf, neck, shoulder, knee and more.

    • REUSABLE - This bulk pack of TENS electrodes can be used multiple times for optimal relief from discomfort. Simply use the resealable package to keep your pads fresh and clean.

    • NO AWKWARD ATTACHMENTS - With a latex-free design and soft cloth backing, each 2x2 inch EMS electrode pad is constructed to move naturally with your body, providing a solution to common therapeutic discomfort.

    description2

    Product Function

    PREGELLED with Premium Quality Gel for immediate use. No Extra Gel Needed.

    • We offer these Premium electrodes for tens unit and EMS machines. Can be used Multiple times per electrode pad / tens pad.

    • Works on all tens , ems, pulse massagers with 3.5 mm pin. Double Sealed for Freshness Reusable Multi-stick Gel for reliability and durability.

    • If you have any issues with your product(s) at all. Please feel free to contact me by clicking on your order number in your past orders section.

    • Made with high quality premium gel so the pads stay on.

    • Tens replacement pad last longer and the tens unit pads reusable and resealable packaging maintain freshness of the premium electrode gel. Medical electrodes for electrical stimulation are latex free and stick firmly for reliable therapeutic current.

    Critical Skin Test Passed

    The pads are CE and ROHS approved, which gives a safety promise to our customers. The pads additionally passed the skin sensitization, irritation and cytotoxicity test to ensure most kinds of skin type users a safe usage. So you can be sure they are high quality Medical Grade Electrodes. No worries about you'll be allergic to it.

     

    Excellent Adhesive Performance

    Quanding Medical uses high quality gel for each pad which adds the reuse times upon to 50 and shows a good self-stick performance.

    If your electrode pads aren't sticky anymore. There are a number of ways you can care for your TENS electrode pads for non-stop use.

    (1) Use the pads on clean and flat areas, no sweat, no oil. If not, the pads can not sticky well.

    (2) If you wash the pads under the tap water, please let them dry naturally.

    (3) Make sure your skin is free from any dirt, oil or lotion before you use this unit.

    (4) Make sure both pads are on your skin, if you only use one pad, it can not work well.

    description2

    Product Application Scenarios

    √ Scope of application of self-adhesive electrode pad:
    Self-adhesive electrodes pad can be used on other parts of the body such as neck, waist, and legs, and are suitable for the treatment of cervical spine syndrome, lumbar spine syndrome and abdominal and leg weight loss and bodybuilding, etc.

    description2

    Storage

    After every use the electrode must be returned to the  "ON" side of the Mylar liner,and placed in the original,re-sealable package to prevent loss of moisture.The electrodes should be stored at a temperature that would be comfortable for a human being.

    description2

    Comparison of products in the industry

    Comparison-of-products-in-the-1

    description2